厂商 :长沙巴溪仪器有限公司
湖南 长沙- 主营产品:
- 仪器仪表
- 电子仪器
- 通用仪器
美国2B Technologies代理,美国2B Technologies销售。
Model 202 Ozone Monitor?
The 2B Technologies Model 202 Ozone Monitor? is designed to enable accurate and precise measurements of ozone ranging from low ppb (precision of ~1.5 ppb) up to 250,000 ppb (0-250 ppm) based on the well-established technique of absorption of UV light at 254 nm. The Model 202 Ozone Monitor? is lightweight (5.5 lb., 2.5 kg.) and has a low power consumption (12V DC, 0.60 amp, 7.2 watt) relative to conventional instruments and is therefore well suited for applications such as:
- Vertical profiling using balloons, kites, RPVs and light aircraft where space and weight are highly limited
- Long-term monitoring at remote locations where power is highly limited
- Urban arrays of ground-based detectors
- Personal exposure monitoring for studies of health effects of air pollutants
- Environmental health and safety monitoring
-
Laboratory studies of the effects of ozone exposure on materials and organisms
Flash card memory and a quiet, long-life internal air pump are now provided standard on the Model 202 Ozone Monitor.
The Model 202 has been designated by the EPA as a Federal Equivalent Method (FEM): EQOA-0410-190.
Options
- GPS for continuous logging of latitude, longitude, and altitude
- Bluetooth for wireless data transmission
- Rechargeable lithium-ion battery provides 12 hours of continuous operation
- External particle filter
- Serial-to-USB adapter
- Cold-weather package (pump, lamp heater for use down to -20 degrees C)
- High-altitude upgrade (pressure sensor for use up to 25 km altitude)
- Low-power option
- Extra-long-life internal air pump
- 4-20 mA analog current output
- Rack-mount case configuration
Specifications
Measurement Principle | UV Absorption at 254 nm |
Federal Equivalent Method (FEM) | Yes, EQOA-0410-190 |
Linear Dynamic Range | 0 to 250 ppm |
Resolution | 0.1 ppb |
Precision (1σ; rms noise) | Greater of 1.5 ppb or 2% of reading |
Accuracy | Greater of 1.5 ppb or 2% of reading |
Limit of Detection (2σ) | 3.0 ppb (in 10-s measurement mode) |
NIST-Traceable Calibration | Yes |
Measurement Interval | 10 s (Data averaging options: 1 min, 5 min, 1 hr) |
Flow Rate (nominal) | ~1 Liter/min |
Flow Rate Requirement | >0.6 L/min |
Baseline Drift |
< 2 ppb/day < 5 ppb/year |
Sensitivity Drift |
< 1%/day < 3%/year |
Measurement Time, Frequency | 10 s, 0.1 Hz |
Response Time, 100% of Step Change | 20 s, 2 points |
Averaging Times | 1 min, 5 min, 1 hr |
Internal Data Logger Capacity |
16,383 lines (10-s meas. = 1.9 days; 1-min avg = 11 days; 5-min avg = 1.9 mo; 1-hr avg = 1.9 yr) |
SD Card Logger Capacity | Minimum 2 GB (> 5-year capacity for 10-s measurement mode) |
Ozone Units | ppb, ppm, pphm, ?g m-3, mg m-3 |
Pressure Units | mbar, torr |
Temperature Units | °C, K |
T and P Corrected | Yes |
Operating Temperature Range | 0 to 50 °C standard; optional -20 to 50 °C with low temperature modifications (pump and lamp heater cold-weather package) |
Operating Altitude Range | ~0-13.5 km (150-1,013 mbar) standard; optional ~0-25 km (30-1,013 mbar) with upgraded pressure sensor |
Power Requirement; Supplied by battery or 110/220 VAC Power Pack |
11-14 V DC or 120/240 V AC, 600 mA, 7.2 watt (6.2 watt with cell heater unplugged) |
Size | 3.5 x 8.5 x 11 inches (9 x 21 x 29 cm) |
Weight | 5.5 lb (2.5 kg); 2.8 lb (1.3 kg) without instrument case |
Analog Inputs for Internal Logging of Other Instruments | 3 Analog Inputs, 0-2.5 V; For example could log external T, P and RH |
Data Outputs | RS232, 0-2.5 V Analog, LCD Display: (Optional 4-20 mA Current, External USB Converter; request quote) |
Data Transfer Baud Rates | 2400, 4800, 19200 |
Output Ranges | User-Defined Scaling Factor in Menu |
DewLine? | Yes |
Quiet Long-Life Internal Air Pump | Yes |
Flow Meter | Yes |
Options | Battery; External Particle Filter; Serial-to-USB Converter; GPS; Bluetooth; 4-20 mA Current Output; Cold-Weather Package (pump, lamp heater); High-Altitude Upgrade; Extra-Long-Life Internal Air Pump; Low-Power Option; Rack-Mount Case Configuration |
Upgradable to Model 205 Dual Beam | Yes |
System Includes
- Model 202 Ozone Monitor with quiet, long-life internal air pump
- AC Power Adapter (100-240 VAC to 12 VDC) with Country-Specific Plug
- Flash Card Memory for virtually unlimited data storage
- SD Card
- SD Card Reader
- Cigarette Lighter Adapter
- Zeroing Cartridge
- Operation Manual on USB Stick
- Calibration Data and NIST-Traceable Calibration Certificate
- Instrument Birth Certificate
- One-Year Warranty