美国2BTechnologies臭氧分析仪Models106-L,106-M

美国2B Technologies代理,美国2B Technologies销售。

Ozone Monitor Models 106-L, 106-M, 106-MH and 106-H

For Industrial Ozone Applications

For industrial ozone applications, 2B Tech offers the Model 106-L, 106-M, 106-MH and 106-H Ozone Monitors, where L, M, MH and H refer to Low (0-100 ppm), Medium (0-1,000 ppm), Medium-High (0-10,000 ppm) and High (0-20 wt%) ozone concentrations, respectively. These instruments have different optical path lengths in order to accommodate an extremely wide range of ozone concentrations, spanning more than eight orders of magnitude. Additionally, the Model 106-H was designed with a flow through path that can be pressurized to up to 50 psi for in-line measurements with ozone generators. All three models are available in either a standard enclosure or NEMA enclosure.

The Model 106 series was designed as an "ozone monitor on a board" in which nearly all of the components are mounted directly to the printed circuit board. Thus, the Model 106 may be purchased without the enclosure for OEM applications. See: Model OEM-106.

The Model 106-L is designed for ambient low measurements down to very low ppb levels and has been designated by the EPA as a Federal Equivalent Method (FEM) for monitoring for compliance with the US Clean Air Act:  EQOA–0914–218.

Specifications for Different Optical Benches

Model Range Resolution Precision & Accuracy
106-L
0-100 ppm
0.0001 ppm (0.1 ppb)
Higher of 0.0015 ppm (1.5 ppb) or 2% of reading
106-M
0-1,000 ppm
0.01 ppm
Higher of 0.01 ppm or 2% of reading
106-MH
0-10,000 ppm (0-1 vol%)
0.1 ppm
Higher of 0.05 ppm or 2% of reading
106-H
0-20 wt% O2 or Air
0-14 vol%
0.01 wt%
0.01 vol%
Higher of 0.01 wt% or 2% of reading

General Specifications

Measurement Principle UV Absorption at 254 nm
Measurement Interval 2 s
Data Averaging Options 10 s, 1 min, 5 min, 1 hr
Flow Rate ~1 Liter/min; Up to 20 L/min for Model 106-H
Data Storage 32,736 lines (10 s avg. = 3.7 days; 5 min avg = 113 days)
Choice of Units ppb, pphm, ppm, ?g m-3, mg m-3 (for Models 106-L and 106-M)
ppm, mg m-3 (for Model 106-MH)
vol%, wt% air, wt% O2, g/m3, g/Nm3 (for Model 106-H)
Data Outputs USB, RS232, 0-2.5 V Analog, 4-20 mA, LCD Display
Power Requirements 11-28 V DC, nominally 500 mA at 12 V DC, 6 watt
Size 3.6 x 7.9 x 9.4 inches (9 x 20 x 24 cm)
Weight 4.2 lb (1.9 kg) [Model 106-L]

Features

  • Measurement based on UV absorption
  • Low power consumption; can be battery operated (optional lithium-ion battery)
  • Internal data logger with real-time clock
  • On-board microprocessor with interactive menus includes data averaging options of 10 s, 1 m, 5 m and 1 hr
  • USB and RS-232 output of time/date, O3 concentration, internal temperature and pressure
  • Analog output (0-2.5 V and 4-20 mA) of ozone concentration in user selected units
  • Two 2-level relays for control purposes (e.g., control of ozone source or turn warning light on and off)
  • Long-life pump (15,000 hr) for Models 106-L, 106-M and 106-MH
  • Bluetooth option for wireless data transmission
To download a brochure describing the OEM-106 Ozone Monitor on a Board, click on the download button below.