UL1569 MC cable UL认证
MC Cable is suitable for use as follows:
? Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
? Power, lighting, control, and signal circuits.
? Fished or embedded in plaster.
? Concealed or exposed installations.
? Environmental air-handling spaces per NEC 300.22 (C).
? Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
? As aerial cable on a messenger.
? Installation in cable tray and approved raceways.
? Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).
? Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
Standard
UL 83, UL 1063, UL 1569
Features
1,Reduces installation costs up to 50% over pipe and wire.
2,Lightweight aluminum armor--as much as 45% lighter than steel MC Cable.
3,UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems:
W-J-3037, W-L-3110, W-L-3113, W-L-3117,W-L-3120, W-L-3121, W-L-3160,
C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202,
C-AJ-4065,C-AJ-4066, F-C-3038.
4,Cable reverse wound on reel for ease of pulling and installation. When
pulling from coils, pull from inside to ensure ease of installation.
Specification and Construction
MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry/75°C
wet, available in sizes 14 AWG through 750 kcmil, and a green insulated
grounding conductor (sizes 1/0 AWG and larger furnished with bare
grounding conductor). The conductors are cabled together and a binder
tape bearing the print legend is wrapped around the assembly. Aluminum
interlocking armor is applied over the assembly. Refer to color chart
for conductor color sequence.
MC Cable is suitable for use as follows:
? Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
? Power, lighting, control, and signal circuits.
? Fished or embedded in plaster.
? Concealed or exposed installations.
? Environmental air-handling spaces per NEC 300.22 (C).
? Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
? As aerial cable on a messenger.
? Installation in cable tray and approved raceways.
? Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).
? Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
Standard
UL 83, UL 1063, UL 1569
Features
1,Reduces installation costs up to 50% over pipe and wire.
2,Lightweight aluminum armor--as much as 45% lighter than steel MC Cable.
3,UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems:
W-J-3037, W-L-3110, W-L-3113, W-L-3117,W-L-3120, W-L-3121, W-L-3160,
C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202,
C-AJ-4065,C-AJ-4066, F-C-3038.
4,Cable reverse wound on reel for ease of pulling and installation. When
pulling from coils, pull from inside to ensure ease of installation.
Specification and Construction
MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry/75°C
wet, available in sizes 14 AWG through 750 kcmil, and a green insulated
grounding conductor (sizes 1/0 AWG and larger furnished with bare
grounding conductor). The conductors are cabled together and a binder
tape bearing the print legend is wrapped around the assembly. Aluminum
interlocking armor is applied over the assembly. Refer to color chart
for conductor color sequence.