厂商 :东莞市腾川自动化设备有限公司
广东 东莞- 主营产品:
东莞凤岗DELTA台达变频器维修 VFD-E系列台达变频器维修 无显示无输出维修
一台台达变频器大11KW 故障现象:静态测量逆变模块正常,整流模块损坏。 故障分析:测量PN之间的反向电阻值正常。初步认定直流负载无过载、短路现象。在拆卸变频器时,发现主电路有过打火的痕迹,继而发现短接限流电阻的继电器触点打火后烧坏连接在一起,这可能就是整流器损坏的原因所在。 故障原因:变频器通电瞬间,充电电流经限流电阻限值后对滤波电容充电,当PN间电压升到接近额定值时,继电器动作,短接限流电阻(俗称软启电阻)。因继电器是常开触点,由于损坏而触点始终闭合,短接了限流电阻,导致整流器损坏。故障处理:更换继电器,整流模块即可。
DELTA台达变频器维修:
VFD001L21A VFD002L21A VFD004L21A VFD007L21A VFD002S21A VFD004S21A VFD007S21A VFD015S21A VFD015S21D VFD022S21D VFD004S43A VFD007S43A VFD015S43D VFD022S43D VFD004M21A VFD007M21A VFD015M21A VFD022M21A VFD007M43B VFD015M43B VFD022M43B VFD037M43A VFD055M43A VFD075M43A VFD007A21A VFD015A21A VFD022A21A VFD007A43A VFD015A43B VFD022A43A VFD037A43A VFD055A43B VFD075A43B VFD110A43A VFD150A43A VFD185A43A VFD220A43A
台达变频器维修:
VFD007B21A VFD015B21A VFD022B21A VFD007B43A VFD015B43A VFD022B43B VFD037B43A VFD055B43A VFD075B43A VFD110B43A VFD150B43A VFD185B43A VFD220B43A VFD300B43A VFD370B43A VFD450B43A VFD550B43C VFD750B43C VFD007V43A VFD015V43A VFD022V43A VFD037V43A VFD055V43A VFD075V43A VFD110V43B VFD150V43A
- ABB2000A断路器常见故障维修总结方法 ABB2000A断路器维修 ABB断路器维修
- 我司常修沙迪克/大金注塑机驱动器维修型号,各类故障
- 大金伺服器维修常见报警E12-E13-E14-E15-E16-E17
- 伦茨9300系列变频器维修 东莞伦茨9300系列变频器维修常见故障
- 东莞伦茨 伦茨伺服电机维修常见故障总结方法 伦茨9300系列变频器维修
- 东莞台达变频器常见故障维修及流程 台达变频器oH过热维修
- 东莞台达变频器常见故障维修总结方法 台达变频器oU过电压维修
- 东莞台达变频器维修 台达变频器显示DF 台达变频器输出缺相维修
- ABB SACE F1断路器维修 ABB SACE F2断路器维修 ABB SACE F4断路器维修
- 东莞施耐德断路器维修-MT06N1-MT32H1- MT08N1