Parameters |
Condition |
Specs |
Units |
||
Min |
Typ |
Max |
|||
Number of Channels |
|
41 |
|
||
Number Channel Spacing |
100GHz |
100 |
GHz |
||
Cha. Center Wavelength |
ITU frequency. |
C -band |
nm |
||
Clear Channel Passband |
|
±12.5 |
GHz |
||
Wavelength Stability |
Maximum range of the wavelength error of all channels and temperatures in average polarization. |
±0.05 |
nm |
||
-1 dB Channel Bandwidth |
Clear channel bandwidth defined by passband shape. For each channel |
0.24 |
|
|
nm |
-3 dB Channel Bandwidth |
Clear channel bandwidth defined by passband shape. For each channel |
0.43 |
|
|
nm |
Optical Insertion Loss at ITU grid |
Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarizati. |
|
4.5 |
6.0 |
dB |
Adjacent Channel Isolation |
Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizati, within the ITU band of the adjacent channels. |
25 |
|
|
dB |
Non-Adjacent, Channel Isolation |
Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizati, within the ITU band of the nonadjacent channels. |
29 |
|
|
dB |
Total Channel Isolation |
Total cumulative insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizati, within the ITU band of all other channels, including adjacent channels. |
22 |
|
|
dB |
Insertion Loss Uniformity |
Maximum range of the insertion loss variation within ITU across all channels, polarizati and temperatures. |
|
|
1.5 |
dB |
Directivity(Mux Only) |
Ratio of reflected power out of any channel(other than channel n)to power in from the input channel n |
40 |
|
|
dB |
Insertion Loss Ripple |
Any maxima and any minima of optical loss across ITU band, excluding boundary points, for each channel at each port |
|
|
1.2 |
dB |
Optical Return loss |
Input & output ports |
40 |
|
|
dB |
PDL/Polarization Dependent Loss in Clear Channel Band |
Worst-e value measured in ITU band |
|
0.3 |
0.5 |
dB |
Polarization Mode Dispersion |
|
|
|
0.5 |
ps |
Maximum Optical Power |
|
|
|
23 |
dBm |
MUX/DEMUX input/ output Monitoring range |
|
-35 |
|
+23 |
dBm |
IL Represents the worst e over a +/-0.01nm window around the ITU wavelength;
PDL was measured on average polarization over a +/- 0.01nm window around the ITU wavelength.
Ordering Information
AWG |
X |
XX |
X |
XXX |
X |
X |
X |
XX |
|
Band |
Number of Channels |
Spacing |
1st Channel |
Filter Shape |
Package |
Fiber Length |
In/Out Connector |
C=C-Band L=L-Band D=C+L-Band X=Special |
16=16-CH 32=32-CH 40=40-CH 48=48-CH XX=Special |
1=100G 2=200G 5=50G X=Special |
C60=C60 H59=H59 C59=C59 H58=H58 XXX=special |
G=Gaussian B=Broad Gaussiar F=Flat Top |
M=Module R=Rack X=Special |
1=0.5m 2=1m 3=1.5m 4=2m 5=2.5m 6=3m S=Specify |
0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/APC 6=LC/PC 7=ST/UPC S=Specify |
- QSFPDD-400G-CU1M 高速铜芯线缆DAC
- AOC高速线缆 25G SFP28 to SFP28
- QSFP28-100G-LR4光模块 QSFP28光模块 1310nm 10km
- 100G QSFP28-100G-SR4光模块 100G SR4光模块
- 25G-SFP-SR SFP28光模块 100m
- 10G-SFP-LR光模块 万兆光模块
- 思科兼容QSFP-100G-CU1M 100G QSFP28 DAC 无源高速线缆 QSFP28-100G-CU1M
- 200GQSFP56-QSFP56AOC有源光缆兼容迈络思 Mellanox 200GQSFP56 AOC
- 思科兼容QSFP-100G-AOC20M 100G QSFP28 有源光缆 20m
- 思科兼容SFP-H25G-CU2M 25G SFP28 DAC 无源高速线缆 30AWG