东洋温度保险管型号及主要技术参数

PAPT NO.

Tf()

Th()

Tm:VDE(UL)

EK

UL/CUL

VDE

CCC

PSE

DF50S

50

30

130

DF57S

57

37

130

DF66S

66

42

110(130)

DF72S

72

50

115(110)

DF77S

77

55

120(110)

DF84S

84

60

125(114)

DF91S

91

67

135(121)

DF98S

98

76

140(130)

DF100S

100

78

135(250)

DF104S

104

80

150

DF110S

110

88

140

DF115S

115

95

170

DF119S

119

95

170

DF121S

121

95

170

DF128S

128

106

155

DF132S

132

110

155

DF139S

139

117

170

DF141S

141

117

171

DF144S

144

120

250

DF152S

152

128

176(175)

DF167S

167

142

210

DF169S

169

145

300

DF170S

170

146

300(190)

DF179S

179

155

300

DF184S

184

160

300(214)

DF192S

192

162

290(222)

DF216S

216

241

DF222S

222

195

300

DF228S

228

193

300

DF240S

240

200

290(260)

DF260S

260

220

350

DF280S

280

230

350

file NO .EKHH05009-2001A-2019A.5020A-5023A

         UL/CUL:E117626

VDE:40017388

 PSE:JET2926-32001-1001-1011

CCC:2003010205079617

 2. DIMENSIONS                              

      3. OPERATING PRINCIPLE & CONSTRUCTIONS

NO

DEION

RAW MATERIAL

REMARKS

1

 CONTACT LEAD

 COPPER WIRE

 SILVER-PLATED

2

 CERAMIC BUSH

 CERAMIC

3

 TRIP SPRING

 STAINLESS STEEL WIRE

4

 STAR CONTACT

 SILVER STRIP

5

 DISC

 PHOSPHOR BRONZE STRIP

6

 COMPRESSION SPRING

 STAINLESS STEEL WIRE

7

 THERMAL PELLET

 ORGANIC CHEMICAL

8

 CASE

 YELLOW BRASS STRIP

 SILVER-PLATED

9

 LEAD

 COPPER WIRE

 

10

 SEAL

 EPOXY

4. CALIBRATION VERIFICATION

         a. The samples of TCO are to be tested using electrically heated static-air oven.

         b. Equilibrium conditions of oven temperature prior to the starting of the test are

            to be established 10 below the rated Tf for 2 hours.                   

         c. The temperature is then to be increased at a rate of 0.5/minute until the

            TCO opened.                                                               

         d. The opening temperature of each TCO shall not differ by more than plus 0

            and minus 5 from the rated Tf.                                 

   

      5. THERMAL ELEMENT STABILITY(Aging)TEST

        

          TCO are to be subjected to the following series of tests.  Each sample shall

          function at some time during the test steps.    

          Samples remaining intact at the conclusion of each step are to be submitted

          to the next step.

      

           STEP 1.                                                                  

              The samples are to be subjected to a temperature Tf minus 15 for 3weeks.

             At the conclusion, at least 50% of the samples shall not have functioned.

           STEP 2.

              Tf minus 10 for 2 weeks

           STEP 3.

              Tf minus 5 for 1 week

STEP 4

 Tf minus 3 for 1 week

           STEP 5.

              Tf plus 3 for 24hours

     6. INSULATION RESISTANCE

          Affer the fusing test of TCO, insulation resistance between lead and contact lead of

         the test sample shall be more than 0.2MΩ.    The insulation resistance to be

         measured with a DC voltage of twice the rated voltage.                  

     7. DIELECTRIC VOLTAGE WITHSTAND

         TCO shall withstand for 1 minute without breakdown a 60Hz essentially

         sinusoidal potential twice the rated voltage applied between leads or terminals

        of an opened TCO.

     8. DIELECTRIC RESISTANCE

         Dielectric resistance measurement to be done between both leads at the

         distance of 30mm including the body.  Dielectric resistance shall be more than

          1.5mΩ.

         

     9. TEMPERATURE RISE

         Temperature rising of TCO shall be not more than 10, when the rated  

         current to be passed through the TCO.

 

 10. SOLDERABILITY

         1) CONTACT LEAD

            Soldering Bath Temperature ; 300                    

            Immersing depth ; 2mm   

2) LEAD

            Soldering Bath Temperature ; 300                    

            Immersing Depth ; 2mm              

            

   11. MECHANICAL STRENGTH (LEAD SECURENESS)

          1) PULL STRENGTH                                             

             When the one end of lead of TCO is held and the other end of lead is

             pulled up to 5Kg to the axial direction gradually for 10 minutes,

             TCO must not be damaged.

          2) BENDING STRENGTH (applied to the side of epoxy seal)     

             TCO is to be rigidly supported so as not to damage it.  Each lead is to be

             bent through 90 degrees at a location 10mm from the body of the TCO and

             then twisted through 180 degrees.  When this test is performed, lead wire must not be cut and parted.  

       12. PRECAUTIONS AND HANDLING INSTRUCTIONS

1)      When bending a lead, bend at a location 3mm minimum from the body of TCO.              

Take caution not to damage either the TCO body or the epoxy seal.

 

          2) When sodering or joining using heat, do not exposure TCO to heat higher than Tf minus 24.

          3) Do not use TCO in a liquid, in a corrosive atmosphere such as sulfurous gas,

             or in a high humidity environment.

          4) Mount the TCO in a location where uniform radiation of heat is sustained over the body of the unit.

          5) Do not use TCO in applications exceeding the rated Tf.  It is recommended to use TCO under the ambient temperature is not higher than Th.

          6) Do not connect TCO direct to the heat source.

             To lessen the heat conducted through the lead to the TCO body, attach the

             contact lead(epoxy end) rather than the case lead to the heat source direction.