空调移机(www.tdktwx.com)以后不制冷的原因有以下几点,请你对照检查:
There are several reasons, please check:
1.制冷剂不足或有泄漏,加制冷剂。
The 1 refrigerant shortage or leakage, add refrigerant.
2.制冷系统堵塞.
Jam 2 refrigeration system.
3.过滤网积尘太多,清洗过滤网。
The 3 filter screen too much dust, clean the filter.
4.压缩机本身效率低
4 the compressor efficiency is low
5.如果刚买来的空调不制冷,那就要考虑是否空调存在质量问题,建议购买一线品牌空调,质量和售后都可得到保险。
5 if bought fresh air conditioning refrigeration not, it would have to consider whether the air-conditioners had quality problems, suggest to buy a first-line brand air conditioning, quality and customer service can get insurance.
估计是:移机之后,忘了收氟(制冷剂)。可以重新抽空加氟,重新装机时连接管路造成制冷剂泄漏(氟漏没了)需找专业维修人员查找漏点(铜管是否有折断漏气),从新焊接抽空加氟,重新装机时没排空气。重新抽空加氟。
Estimation is: move, forgot to collect fluoride (refrigerant). Can be re to fluoride, re installed when connecting pipe caused by leakage of refrigerant (fluorine leakage didnt) need to find professional repair personnel find leak (brass have broken leakage), the new welding time plus fluoride, row not re installed when the air. Re fit fluoride.
不制冷可能是氟利昂不够,供电电压不够,空调功率不够,外界环境温度过高,空调长时间不清洗保养,连接室内机和室外机的铜管过长。
No refrigeration is probably not enough freon, power supply voltage is not enough, the air-conditioning power is not enough, the ambient temperature is too high, long time no air-conditioning cleaning and maintenance, connect indoor unit and outdoor unit pipe is too long.
1.首先看看管子有没有弄瘪 2.再看看线有没有接错 3.阀门有没有打开 4.空气有没有排干净 5.制冷剂是否泄露完了 6.模式是不是设置错误
1 first have a look have made 2 more flat tubes have a look line there is no wrong 3 valves have opened 4 air there is no row clean 5 refrigerant leaks. Is it right? 6 mode setting error
你是自己移机还是请的专业师傅做的,如果是自己移机可能有以下几种情况
You are moving or please professional chef, if their moves may have the following situations
1、以及以后忘记开室外机的管路开关了,看一下内六方螺丝是不是已经松到位了。
1, and later forget line open outdoor machine switch, see six screws up in is it right? Was in place.
2、管路可能有漏氟的地方,如果是氟量不够了就得请专业师傅给查一下什么地方漏的,然后补充到规定量就可以了。
2, the pipeline may have fluorine leakage place, if the amount of fluorine are not enough to please a professional chef to check where the leak, and then added to the specified amount can be.
3、空调制冷系数和电压电线的平方数都有关系,换粗一些的电线也会好一点,空调的电路最好是单走一路不要和其他用电设备公用一条线。
Both square number 3, air conditioning and refrigeration coefficient and voltage line, will be better for some thick wire, air conditioning circuit is the best single way, dont and other electric equipment to the public a line.
4、移机以后的房间面积和空调适用的房间面积要成正比
For 4, machine room after the area and air-conditioned room area should be proportional to
5、如果自己没有太大把握还是请个专业空调技师给看一下,我的空调就是我自己移机的,效果很好的。
5, if you are not too sure or please a professional air conditioning mechanic to see, my air conditioning is my own moves, the effect is very good.
如果外机风扇转速启动正常,内机有风吹出,同时模式选为制冷,那么就是缺氟或者氟过多因为你加过,所以你的空调关键是看制冷模式时,出去看看外机,再看看内机是否正常。
If the outer fan normal start inside the machine speed, wind is blown out, at the same time the mode to refrigeration, so is the lack of fluoride or fluorine too much because you add too, so air conditioning your key is to look at the refrigeration mode, go out to have a look outside the machine, then have a look inside the machine is normal.
|