X3/PR5410 控制仪表

厂商 :深圳市汉斯福特科技有限公司

广东 深圳
  • 主营产品:
联系电话 :13421312443
商品详细描述

X3/PR5410 控制仪表

深圳市汉斯福特科技有限公司

座机:0755-26552352

手机:18018750116

传真:0755-23343535

Q  Q: 3174269615

公司地址:龙华新区大浪街道大浪社区伟达工业园A栋2楼

公司网址:www.huntsort.com  

 

概述

The process indicator for platform and tank and hopper scales as well as Simple configuration over Ethernet TCP/IP or using the front panel keypad ensures fast installation. Variety of interfaces, including fieldbuses, available.

在化工生产中,又称控制器或调节仪表。是将被控变量按一定度自动控制在设定值附近的化工仪表。它把所需控制的被控变量的测量值与要求的设定值进行比较,得出偏差,按照一定的函数关系(称为控制规律)发生控制作用,操纵控制阀或其他执行器以实现对生产过程的控制。在化工生产中常见的被控变量有温度、流量、压力、液位和成分等。常规的控制仪表内部用模拟信号联系和运算,故称模拟控制仪表,也称调节器。控制仪表内部用数字信号联系和运算的,称为数字式控制仪表,也称数字调节器。

特性

1. Ethernet TCP/IP Connection for Remote 

2. Configuration via VNC

3. OPC Server

4. W&M approval with 10.000e acc. to EN 45501 / OIML R 76

5. Serial Interface RS232 for printer or remote display

6. 3 digital In- and 3 Outputs for limit function

7. Optional Interfaces:

8. Serial Interface (RS 232 or RS 422/485)

9. Analogue - / BCD Output

10. PROFIBUS-DP, DeviceNET, Interbus-S, Modbus-TCP, CC-link)

11. Transflective LCD Display, back lighted

12. Panel Housing with IP 65 Front

按控制仪表使用能源可分为电动、气动和液动三种。按结构又可分为基地式和单元组合式两种。基地式的特点在于仪表的所有部件之间,以不可分离的机械结构相连接,装在一个箱壳之内,利用一台仪表就能解决一个简单自动化系统的测量、记录、控制等全部问题,如温度控制器、压力控制器、流量控制器、液位控制器等。单元组合式控制器包括变送、调节、运算、显示、执行等单元,

参数

Technical Data

Housing

: 192 + 96 + 150 mm

Panel cutout:

187+0,5 + 91+0,5 mm

Material: Aluminium

Protection class: IP30

Front panel: IP65

RoHS conform

Supply Voltage

110 V/240 VAC, -15 %/+10 %,

50/60 Hz or: 24 VDC

Power 

13 VA/11 W

Display

LCD, transflective, back lighted

Elements: 6-digits (7 Segments)

figure height: 18 mm

Colour: black | white with

weight- and status symbols

Keyboard

6 double function keys

(short lift keys)

Status Indicator

-> 0 <- zero display within

± 1/4d standstill

B gross weight display

NET net weight display

T tare weight display

 can be set for: g, kg, t, lb

Decimal point can be set

 outputs

Quantity: 3

opto-isolated output, passive,

Voltage: max. 30 VDC

Current: max. 30 mA

 Inputs

Quantity: 3,

opto-isolated input, passiv,

: zero setting, taring...

Voltage: max. 30 VDC

Current: max. 10 mA

Load cell connection

All strain gauge load cells;

6- or 4-wire connection

Load cell supply

12 V, short-circuit proof.

External load cell supply .

Minimum load impedance

min. 75 O

e.g. 6 load cells with 600 O

or 4 load cells with 350 O

Measuring principle

Measuring amplifier:

Delta-Sigma converter

Measuring time:

min 5 ms - max. 1600 ms

Accuracy

10,000 e class III acc. to EN 45501;

according to. OIML R 76,

min. verification interval: 0.5 μV/e

Input range

7.5 nV (appr. 4.8 Mio. div.)

Usable resolution: 0.2 μV/d

Input signal

Measuring signal: 0 bis 36 mV

(for 100 % nominal load)

ATEX approval

only indicator PR5410/03

Zone 2/22

II 3G Ex nA II T4 X

II 3D Ex tD A22 IP5x T80°C X

Linearity < 0.003 %

Temperature effects

Zero: TK0 m < 0.05 μV/K RTI

Span: TKspan < +/- 2.5 ppm/K

Alibi Memory

Internal 50.000 

Digital filter for load cell

4th order (low pass), Bessel, aperiodic

or Butterworth

Ethernet interface

Ethernet TCP/IP and Modbus TCP

definition of an IP address:

– AutoIP

– DHCP Server assignment

– manual input of an IP address

Automatic detection of signal

transmission and corresponding

change over (auto cross-over)

(cross-over or patch cable)

Environmental 

Temperature

W&M: –10 °C to +40 °C

Operation: –10 °C to +50 °C

Storage: –20 °C to +70 °C

Protection class

Front panel IP65

Housing IP30

Packing size

291 + 331 + 160 mm

Weight

Net: 1.45 kg

Gross: 2.3 kg

可与各类传感器、变送器配合使用,实现对温度、压力、液位、容量、力等物理量的测量和显示,并配合各种执行器对电加热设备和电磁、电动阀门进行PID调节和控制、报警控制,数据采集和记录

订货型号

Type Description Order number

PR 5410/00 X3 Process Indicator, 110–230 V 9405 154 10001

PR 5410/01 X3 Process Indicator, 24 VDC 9405 154 10011

PR5410/03 X3 Process Indicator, 24 VDC, ATEX Zone 2/22 9405 154 10031

化工自动化中一般常用三种基本控制规律(或称作用方式):①比例作用(P),控制器输出的变化与偏差的变化成比例。偏差越大,控制作用越强。在化工中可单独使用,如液位控制等,用于不要求严格消除残余偏差的场合。②积分作用(I),控制器输出的变化率与偏差成比例。偏差存在时间越长,控制作用也越强,这种控制作用主要用于要求消除残余偏差的场合,但在化工中较少单独使用。③微分作用(D),控制器输出与偏差的变化率成比例,用于需要加速调节过程的场合,在化工中不单独使用。常用的控制规律往往是比例作用与其他作用的组合。如一般参数(如流量)的控制常用比例积分作用(PI);对惯性较大的对象(如温度、成分)控制常用比例积分微分作用(PID)。


PR 5510/02 Serial Interface Card 2 + RS232 9405 355 10021

PR 5510/04 Serial Interface Card 1 + RS232 und 1 + RS485 9405 355 10041

PR 5510/07 Analogue 4 In- | 1 Output 9405 355 10071

PR 5510/08 BCD open emitter 9405 355 10081

PR 5510/09 BCD open collector 9405 355 10091

PR 5510/12 Digital 6 In- and 12 Outputs 9405 355 10121

PR 5510/14 Ethernet Modbus TCP 9405 355 10141

PR 1721/31 Profibus-DP 9405 317 21311

PR 1721/32 Interbus S 9405 317 21321

PR 1721/34 Device NET 9405 317 21341

PR 1721/35 CC-Link 9405 317 21351

PR 1721/36 Profinet 9405 317 21361

PR 1721/37 Ethernet | IP 9405 317 21371