6SL3210-1SE23-8A

厂商 :上海芈峥工业控制设备有限公司

上海 金山区
  • 主营产品:
联系电话 :13795353010
商品详细描述

Overview

PM340 Power Modules in blocksize format, frame sizes FSA to FSF

The PM340 Power Modules in blocksize format feature the following connections and interfaces as standard:

  • Line supply connection
  • PM?IF interface for connection of the PM340 and CU305 Control Unit. The PM340 Power Module also supplies power to the CU305 Control Unit by means of an integrated power supply.
  • Terminals DCP/R1 and R2 for connection of an external braking resistor
  • Motor connection made with screw terminals or screw studs
  • Control circuit for the Safe Brake Relay for controlling a holding brake
  • 2 PE/protective conductor connections

PM340 Power Modules without integrated line filter can be connected to grounded TN/TT and non-grounded IT systems.
PM340 Power Modules with integrated line filter are suitable only for connection to TN systems with grounded star point.

The integrated braking unit (braking chopper) is rated with the capability to continuously utilize the external braking resistor. The temperature of the external braking resistor must be monitored to provide protection against thermal overloading.

Integration

PM340 Power Modules communicate with the CU305 Control Unit via the PM-IF interface.

PM340 Power Module with CU305 DP Control Unit and BOP20 Basic Operator Panel

Note:

Operation of SINAMICS S110 in conjunction with PM240?2 Power Modules is possible with firmware version V4.4 SP3 and higher.

Connection example: PM340 Power Module

Many system components are designed as base components for PM340 Power Modules. I.e. the component is mounted on the baseplate and the PM340 Power Module in front of them in a space-saving construction. Up to two base components can be mounted in front of one another.

 

FSA

FSB

FSC

FSD

FSE

FSF

Line filter

Line reactor

O

Braking resistor

O

O

O

O

Motor reactor

O

O

O



? = Suitable as base type

O = Not suitable as base type

– = Not available (use a PM340 Power Module with integrated line filter)

 

Basic layout of a PM340 Power Module with line reactor as base component

The line side reactors are equipped with terminals on the line side and with a pre-assembled cable on the PM340 Power Module side. When installed, the mains terminals are at the top on frame sizes FSA to FSC, and at the bottom on frame sizes FSD and FSE.

PM340 Power Module in frame size FSA with line reactor and line filter

If a line filter is installed in addition to the line reactor on frame size FSA, the components must be arranged as shown in the diagram above. In this case, the line supply connection is at the bottom.

PM340 Power Module in frame size FSA with line reactor and motor reactor

PM340 Power Modules of frame size FSB and higher are available with integrated line filters, alleviating the need for an external line filter.

For configurations involving more than two base-type system components, e.g. line reactor + motor reactor + braking resistor, individual components must be mounted to the side of the PM340 Power Module. In this instance, the line and motor reactors must be installed behind the PM340 Power Module and the braking resistor to the side.

Technical Specifications

 

Air-cooled PM340 Power Module in blocksize format

6SL3210-1S...

Line connection voltage

(up to 2000 m/6562 ft above sea level)

200 V ... 240 V 1 AC ±10% (in operation -15% < 1 min) or

380 ... 480 V 3 AC ±10% (in operation -15% <1 min)

Line

 

  • Power Modules without integrated line filter

Grounded TN/TT systems and non-grounded IT systems

  • Power Modules with integrated line filter

TN systems with grounded star point

Line frequency

47 ... 63 Hz

Line power factor

at rated power

 

  • Fundamental power factor (cos φ1)

>0.96

  • Total (λ)

 

  • 200 ... 240 V 1 AC

0.45 ... 0.7

  • 380 ... 480 V 3 AC

0.65 ... 0.95

Overvoltage category

acc. to EN 60664-1

Class III

Precharging frequency

of the DC link, max.

1× every 30 s

DC link voltage, approx.

1.35 × line voltage

Output frequency

 

  • Control type Servo

0 ... 330 Hz 1)

Electronics power supply

24 V DC -15 %/+20 %

Radio interference suppression

 

  • Standard

No radio interference suppression

  • With line filter

Category C2 acc. to EN 61800?3

Type of cooling

Forced air cooling by means of built-in fan

A ambient or coolant temperature (air)

in operation for line-side components, Power Modules

0 ... 40 °C (32 ... 104 °F) without derating,
>40 ... 55 °C (>104 ... 131 °F) see characteristics

Installation altitude

Up to 1000 m (3281 ft) above sea level without derating,
>1000 ... 4000 m (3281 ... 13124 ft) above sea levelsee derating characteristics

Conformity

CE (low-voltage and EMC Directives)

Approvals, according to

cULus

Safety Integrated

Safety Integrity Level 2 (SIL 2) according to IEC 61508, 
Performance Level d (PL d) and Category 3 according to EN ISO 13849?1

Additional information is provided in chapter Highlights, section Safety Integrated.



1) Note the correlation between max. output frequency, pulse frequency and current derating.

 

Line voltage 200 ... 240 V 1 AC

Air-cooled PM340 Power Module in blocksize format

 

 

6SL3210-1SB11-0...

6SL3210-1SB12-3...

6SL3210-1SB14-0...

Output current

 

 

 

 

  • Rated current Irated

A

0.9

2.3

3.9

  • Base-load current IH

A

0.8

2

3.4

  • For S6 duty (40 %) IS6

A

1.4

3.3

5.5

  • Maximum currentImax

A

2

4.6

7.8

Type rating 1)

Based on Irated

kW (hp)

0.12 (0.16)

0.37 (0.5)

0.75 (1)

Rated pulse frequency

kHz

4

4

4

Power loss

kW

0.06

0.075

0.11

Cooling air requirement

m3/s (ft3/s)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

Sound pressure level

LpA (1 m)

dB

<45

<45

<45

24 V DC power supply

for the Control Unit

A

1

1

1

Rated input current2)

with/without line reactor

A

1.4/2.2

4/6

6.5/10

Resistance value

of the external braking resistor

Ω 

≥180

≥180

≥180

Cable length

to braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

Line supply connection

L, N

 

Screw terminals

Screw terminals

Screw terminals

  • Conductor cross-section

mm2

1 ... 2.5

1 ... 2.5

1 ... 2.5

DC link connection, 
connection for braking resistor

DCP/R1, DCN, R2

 

Screw terminals

Screw terminals

Screw terminals

  • Conductor cross-section

mm2

1 ... 2.5

1 ... 2.5

1 ... 2.5

Motor connection

U2, V2, W2

 

Screw terminals

Screw terminals

Screw terminals

  • Conductor cross-section

mm2

1 ... 2.5

1 ... 2.5

1 ... 2.5

PE connection

 

M4 screw

M4 screw

M4 screw

Motor cable length3), max.

(without external options)

 

 

 

 

  • Shielded

m (ft)

50 (164)

50 (164)

50 (164)

  • Unshielded

m (ft)

75 (246)

75 (246)

75 (246)

Degree of protection

 

IP20

IP20

IP20

Dimensions

 

 

 

 

  • Width

mm (in)

73 (2.87)

73 (2.87)

73 (2.87)

  • Height

mm (in)

173 (6.81)

173 (6.81)

173 (6.81)

  • Depth

 

 

 

 

  • PM340

mm (in)

145 (5.71)

145 (5.71)

145 (5.71)

  • PM340 with CU305 PN

mm (in)

216 (8.50)

216 (8.50)

216 (8.50)

  • PM340 with CU305 DP/CAN

mm (in)

200 (7.87)

200 (7.87)

200 (7.87)

Frame size

 

FSA

FSA

FSA

Weight, approx.

kg (lb)

1.2 (2.65)

1.3 (2.87)

1.3 (2.87)



1) Rated power of a typical standard asynchronous (induction) motor at 230 V 3 AC.

2) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uk = 1 %.

3) Max. motor cable length 15 m (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

 

Line voltage 380 ... 480 V 3 AC

Air-cooled PM340 Power Module in blocksize format

 

 

6SL3210-1SE11-3UA0

6SL3210-1SE11-7UA0

6SL3210-1SE12-2UA0

6SL3210-1SE13-1UA0

6SL3210-1SE14-1UA0

Output current

 

 

 

 

 

 

  • Rated current Irated

A

1.3

1.7

2.2

3.1

4.1

  • Base-load current IH

A

1.1

1.5

1.9

2.7

3.6

  • For S6 duty (40 %) IS6

A

1.3

2

2.5

3.5

4.5

  • Maximum currentImax

A

2.6

3.4

4.4

6.2

8.2

Type rating 1)

 

 

 

 

 

 

  • Based on Irated

kW (hp)

0.37 (0.5)

0.55 (0.75)

0.75 (1)

1.1 (1.5)

1.5 (2)

  • Based on IH

kW (hp)

0.37 (0.5)

0.55 (0.75)

0.75 (1)

1.1 (1.5)

1.5 (2)

Rated pulse frequency

kHz

4

4

4

4

4

Power loss

kW

0.1

0.1

0.1

0.11

0.11

Cooling air requirement

m3/s (ft3/s)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

Sound pressure level

LpA (1 m)

dB

<45

<45

<45

<45

<45

24 V DC power supply

for the Control Unit

A

1

1

1

1

1

Rated input current2)

with/without line reactor

A

1.3/1.7

1.7/2.2

2.2/2.6

3.1/3.9

4.1/4.8

Resistance value

of the external braking resistor

Ω 

≥390

≥390

≥390

≥390

≥390

Cable length

to braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

15 (49)

15 (49)

Line supply connection

U1/L1, V1/L2, W1/L3

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1 ... 2.5

1 ... 2.5

1 ... 2.5

1 ... 2.5

1 ... 2.5

DC link connection, 
connection for braking resistor

DCP/R1, DCN, R2

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1 ... 2.5

1 ... 2.5

1 ... 2.5

1 ... 2.5

1 ... 2.5

Motor connection

U2, V2, W2

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1 ... 2.5

1 ... 2.5

1 ... 2.5

1 ... 2.5

1 ... 2.5

PE connection

 

M4 screw

M4 screw

M4 screw

M4 screw

M4 screw

Motor cable length3), max.

 

 

 

 

 

 

  • Shielded

m (ft)

50 (164)

50 (164)

50 (164)

50 (164)

50 (164)

  • Unshielded

m (ft)

75 (246)

75 (246)

75 (246)

75 (246)

75 (246)

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

  • Width

mm (in)

73 (2.87)

73 (2.87)

73 (2.87)

73 (2.87)

73 (2.87)

  • Height

mm (in)

173 (6.81)

173 (6.81)

173 (6.81)

173 (6.81)

173 (6.81)

  • Depth

 

 

 

 

 

 

  • PM340

mm (in)

145 (5.71)

145 (5.71)

145 (5.71)

145 (5.71)

145 (5.71)

  • PM340 with CU305 PN

mm (in)

216 (8.50)

216 (8.50)

216 (8.50)

216 (8.50)

216 (8.50)

  • PM340 with CU305 DP/CAN

mm (in)

200 (7.87)

200 (7.87)

200 (7.87)

200 (7.87)

200 (7.87)

Frame size

 

FSA

FSA

FSA

FSA

FSA

Weight, approx.

kg (lb)

1.2 (2.65)

1.2 (2.65)

1.2 (2.65)

1.2 (2.65)

1.2 (2.65)



1) Rated power of a typical standard asynchronous (induction) motor at 400 V 3 AC.

2) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uk = 1 %.

3) Max. motor cable length 25 m (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

 

Line voltage 380 ... 480 V 3 AC

Air-cooled PM340 Power Module in blocksize format

 

 

6SL3210-1SE16-0...

6SL3210-1SE17-7...

6SL3210-1SE21-0...

6SL3210-1SE21-8...

6SL3210-1SE22-5...

6SL3210-1SE23-2...

Output current

 

 

 

 

 

 

 

  • Rated current Irated

A

5.9

7.7

10.2

18

25

32

  • Base-load current IH

A

5.2

6.8

9.1

14

21

27

  • For S6 duty (40 %) IS6

A

6.4

8.3

10.8

19.6

27.8

37.1

  • Maximum currentImax

A

11.8

15.4

20.4

26.4

38

52

Type rating 1)

 

 

 

 

 

 

 

  • Based on Irated

kW (hp)

2.2 (3)

3 (5)

4 (5)

7.5 (10)

11 (15)

15 (20)

  • Based on IH

kW (hp)

2.2 (3)

3 (5)

4 (5)

5.5 (10)

7.5 (10)

11 (15)

Rated pulse frequency

kHz

4

4

4

4

4

4

Power loss

kW

0.14

0.16

0.18

0.24

0.3

0.4

Cooling air requirement

m3/s (ft3/s)

0.009 (0.3)

0.009 (0.3)

0.009 (0.3)

0.038 (1.3)

0.038 (1.3)

0.038 (1.3)

Sound pressure level

LpA (1 m)

dB

<50

<50

<50

<60

<60

<60

24 V DC power supply

for the Control Unit

A

1

1

1

1

1

1

Rated input current2)

with/without line reactor

A

5.6/6.7

7.5/8.9

9.8/12.4

17.1/23.1

24.6/32.6

33/39

Resistance value

of the external braking resistor

Ω 

≥160

≥160

≥160

≥56

≥56

≥56

Cable length

to braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

15 (49)

15 (49)

15 (49)

Line supply connection

U1/L1, V1/L2, W1/L3

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1 ... 6

1 ... 6

1 ... 6

2.5 ... 10

2.5 ... 10

2.5 ... 10

DC link connection, 
connection for braking resistor

DCP/R1, DCN, R2

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1 ... 6

1 ... 6

1 ... 6

2.5 ... 10

2.5 ... 10

2.5 ... 10

Motor connection

U2, V2, W2

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1 ... 6

1 ... 6

1 ... 6

2.5 ... 10

2.5 ... 10

2.5 ... 10

PE connection

 

M5 screw

M5 screw

M5 screw

M5 screw

M5 screw

M5 screw

Motor cable length3), max.

 

 

 

 

 

 

 

  • Shielded

m (ft)

50 (164)

50 (164)

50 (164)

50 (164)

50 (164)

50 (164)

  • Unshielded

m (ft)

75 (246)

75 (246)

75 (246)

75 (246)

75 (246)

75 (246)

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

 

  • Width

mm (in)

153 (6.02)

153 (6.02)

153 (6.02)

188.4 (7.42)

188.4 (7.42)

188.4 (7.42)

  • Height

mm (in)

270 (10.63)

270 (10.63)

270 (10.63)

333.4 (13.13)

333.4 (13.13)

333.4 (13.13)

  • Depth

 

 

 

 

 

 

 

  • PM340

mm (in)

165 (6.50)

165 (6.50)

165 (6.50)

185 (7.28)

185 (7.28)

185 (7.28)

  • PM340 with CU305 PN

mm (in)

236 (9.29)

236 (9.29)

236 (9.29)

256 (10.08)

256 (10.08)

256 (10.08)

  • PM340 with CU305 DP/CAN

mm (in)

220 (8.66)

220 (8.66)

220 (8.66)

240 (9.45)

240 (9.45)

240 (9.45)

Frame size

 

FSB

FSB

FSB

FSC

FSC

FSC

Weight, approx.

kg (lb)

4 (8.82)

4 (8.82)

4 (8.82)

6.5 (14.3)

6.5 (14.3)

6.5 (14.3)



1) Rated power of a typical standard asynchronous (induction) motor at 400 V 3 AC.

2) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uk = 1 %.

3) Max. motor cable length 25 m (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

 

Line voltage 380 ... 480 V 3 AC

Air-cooled PM340 Power Module in blocksize format

 

 

6SL3210-1SE23-8...

6SL3210-1SE24-5...

6SL3210-1SE26-0...

6SL3210-1SE27-5...

6SL3210-1SE31-0...

Output current

 

 

 

 

 

 

  • Rated current Irated

A

38

45

60

75

90

  • Base-load current IH

A

33

40

48

65

80

  • For S6 duty (40 %) IS6

A

49

58

78

98

117

  • Maximum currentImax

A

64

76

90

124

150

Type rating 1)

 

 

 

 

 

 

  • Based on Irated

kW (hp)

18.5 (25)

22 (30)

30 (40)

37 (50)

45 (60)

  • Based on IH

kW (hp)

15 (20)

18.5 (25)

22 (30)

30 (40)

37 (50)

Rated pulse frequency

kHz

4

4

4

4

4

Power loss

kW

0.38

0.51

0.69

0.99

1.21

Cooling air requirement

m3/s (ft3/s)

0.022 (0.8)

0.022 (0.8)

0.039 (1.4)

0.022 (0.8)

0.039 (1.4)

Sound pressure level

LpA (1 m)

dB

<60

<60

<61

<60

<62

24 V DC power supply

for the Control Unit

A

1

1

1

1

1

Rated input current2)

with/without line reactor

A

40/46

47/53

63/72

78/88

94/105

Resistance value

of the external braking resistor

Ω 

≥27

≥27

≥27

≥15

≥15

Cable length

to braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

15 (49)

15 (49)

Line supply connection

U1/L1, V1/L2, W1/L3

 

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

  • Conductor cross-section

mm2

10 ... 35

10 ... 35

10 ... 35

10 ... 35

10 ... 35

DC link connection, 
connection for braking resistor

DCP/R1, DCN, R2

 

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

  • Conductor cross-section

mm2

10 ... 50

10 ... 50

10 ... 50

10 ... 50

10 ... 50

Motor connection

U2, V2, W2

 

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

  • Conductor cross-section

mm2

10 ... 35

10 ... 35

10 ... 35

10 ... 35

10 ... 35

PE connection

 

M6 screw

M6 screw

M6 screw

M6 screw

M6 screw

Motor cable length3), max.

 

 

 

 

 

 

  • Shielded

m (ft)

70 (230)

70 (230)

70 (230)

70 (230)

70 (230)

  • Unshielded

m (ft)

100 (328)

100 (328)

100 (328)

100 (328)

100 (328)

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

  • Width

mm (in)

275 (10.83)

275 (10.83)

275 (10.83)

275 (10.83)

275 (10.83)

  • Height, PM340
    without/with int. filter

 

418.3/511

418.3/511

418.3/511

498.3/633

498.3/633

  • Depth

 

 

 

 

 

 

  • PM340

mm (in)

203.5 (8.01)

203.5 (8.01)

203.5 (8.01)

203.5 (8.01)

203.5 (8.01)

  • PM340 with CU305 PN

mm (in)

274.5 (10.81)

274.5 (10.81)

274.5 (10.81)

274.5 (10.81)

274.5 (10.81)

  • PM340 with CU305 DP/CAN

mm (in)

258.5 (10.18)

258.5 (10.18)

258.5 (10.18)

258.5 (10.18)

258.5 (10.18)

Frame size

 

FSD

FSD

FSD

FSE

FSE

Weight, approx.

PM340 without/with int. filter

kg (lb)

15.9/19.3 (35/43)

15.9/19.3 (35/43)

15.9/19.3 (35/43)

19.8/27.1 (44/60)

19.8/27.1 (44/60)




标签: