西门子接触器 3RT1446-6AV66
product brand name | SIRIUS | |
Product designation | power contactor | |
General technical data: | ||
Size of contactor | S3 | |
Insulation voltage | ||
● Rated value | 1 000 V | |
Surge voltage resistance Rated value | 6 kV | |
Protection class IP | ||
● on the front | IP00 | |
● of the terminal | IP00 | |
Degree of pollution | 3 | |
Mechanical service life (switching cycles) | ||
● of the contactor typical | 10 000 000 | |
● of the contactor with added electronics-compatible auxiliary switch block typical | 5 000 000 | |
● of the contactor with added auxiliary switch block typical | 10 000 000 | |
Ambient conditions: | ||
Installation altitude at height above sea level maximum | 2 000 m | |
Ambient temperature | ||
● during operation | -25 ... +60 °C | |
● during storage | -55 ... +80 °C | |
Main circuit: | ||
Number of NO contacts for main contacts | 3 | |
Number of NC contacts for main contacts | 0 | |
Operating current | ||
● at AC-1 at 400 V | ||
— at ambient temperature 40 °C Rated value | 140 A | |
● at AC-1 up to 690 V | ||
— at ambient temperature 40 °C Rated value | 140 A | |
— at ambient temperature 60 °C Rated value | 130 A | |
● at AC-3 | ||
— at 400 V Rated value | 44 A | |
— at 690 V Rated value | 44 A | |
Connectable conductor cross-section in main circuit at AC-1 | ||
● at 60 °C minimum permissible | 35 mm? | |
● at 40 °C minimum permissible | 50 mm? | |
Operating current | ||
● at 1 current path at DC-1 | ||
— at 24 V Rated value | 130 A | |
— at 110 V Rated value | 12 A | |
● with 2 current paths in series at DC-1 | ||
— at 24 V Rated value | 130 A | |
— at 110 V Rated value | 130 A | |
● with 3 current paths in series at DC-1 | ||
— at 24 V Rated value | 130 A | |
— at 110 V Rated value | 130 A | |
Operating current | ||
● at 1 current path at DC-3 at DC-5 | ||
— at 24 V Rated value | 6 A | |
— at 110 V Rated value | 1.25 A | |
● with 2 current paths in series at DC-3 at DC-5 | ||
— at 110 V Rated value | 130 A | |
— at 24 V Rated value | 130 A | |
● with 3 current paths in series at DC-3 at DC-5 | ||
— at 110 V Rated value | 130 A | |
— at 24 V Rated value | 130 A | |
Operating power | ||
● at AC-1 | ||
— at 230 V at 60 °C Rated value | 50 kW | |
— at 400 V Rated value | 86 kW | |
— at 690 V Rated value | 148 kW | |
— at 690 V at 60 °C Rated value | 148 kW | |
● at AC-2 at 400 V Rated value | 22 kW | |
● at AC-3 | ||
— at 230 V Rated value | 12.7 kW | |
— at 400 V Rated value | 22 kW | |
— at 500 V Rated value | 29.9 kW | |
— at 690 V Rated value | 38.2 kW | |
Thermal short-time current limited to 10 s | 600 A | |
Active power loss at AC-3 at 400 V for rated value of the operating current per conductor | 12.5 W | |
No-load switching frequency | ||
● at DC | 1 000 1/h | |
Operating frequency | ||
● at AC-1 maximum | 650 1/h | |
Control circuit/ Control: | ||
Type of voltage of the control supply voltage | AC | |
Control supply voltage at AC | ||
● at 60 Hz Rated value | 480 V | |
● Rated value | 60 Hz | |
Operating range factor control supply voltage rated value of the magnet coil at AC | ||
● at 60 Hz | 0.8 ... 1.1 | |
Apparent pick-up power of the magnet coil at AC | 300 V·A | |
Inductive power factor with closing power of the coil | 0.52 | |
Apparent holding power of the magnet coil at AC | 21 V·A | |
Inductive power factor with the holding power of the coil | 0.29 | |
Closing delay | ||
● at DC | 90 ... 230 ms | |
Arcing time | 10 ... 15 ms | |
Auxiliary circuit: | ||
Number of NC contacts | ||
● for auxiliary contacts | ||
— instantaneous contact | 2 | |
Number of NO contacts | ||
● for auxiliary contacts | ||
— instantaneous contact | 2 | |
Operating current at AC-12 maximum | 10 A | |
Operating current at AC-15 | ||
● at 230 V Rated value | 6 A | |
● at 400 V Rated value | 3 A | |
Operating current at DC-12 | ||
● at 60 V Rated value | 6 A | |
● at 110 V Rated value | 3 A | |
● at 220 V Rated value | 1 A | |
Operating current at DC-13 | ||
● at 24 V Rated value | 10 A | |
● at 60 V Rated value | 2 A | |
● at 110 V Rated value | 1 A | |
● at 220 V Rated value | 0.3 A | |
Contact reliability of the auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) | |
UL/CSA ratings: | ||
Contact rating of the auxiliary contacts acc. to UL | A600 / Q600 | |
Short-circuit: | ||
Design of the fuse link | ||
● for short-circuit protection of the main circuit | ||
— with type of assignment 1 required | fuse gL/gG: 250 A | |
— with type of assignment 2 required | fuse gL/gG: 250 A | |
● for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A | |
Installation/ mounting/ dimensions: | ||
Mounting type | screw and snap-on mounting onto 35 mm and 75 mm standard mounting rail | |
● Side-by-side mounting | Yes | |
Height | 146 mm | |
Width | 90 mm | |
Depth | 139 mm | |
Required spacing | ||
● for grounded parts | ||
— at the side | 6 mm | |
Connections/ Terminals: | ||
Type of electrical connection | ||
● for main current circuit | screw-type terminals | |
● for auxiliary and control current circuit | screw-type terminals | |
Type of connectable conductor cross-section | ||
● for AWG conductors for main contacts | 7 ... 1/0 | |
Type of connectable conductor cross-section | ||
● for auxiliary contacts | ||
— solid | 2x (0.5 ... 1.5 mm?), 2x (0.75 ... 2.5 mm?), max. 2x (0.75 ... 4 mm?) | |
— finely stranded with core end processing | 2x (0.5 ... 1.5 mm?), 2x (0.75 ... 2.5 mm?) | |
● for AWG conductors for auxiliary contacts | 2x (20 ... 16), 2x (18 ... 14), 1x 12 |