厂商 :东莞中赛电子仪器有限公司
广东 东莞- 主营产品:
- 频谱分析仪
- 频率计
- 音频分析仪
联系电话 :13556784911
商品详细描述
20kHz~8GHz频率范围
·高测量速度(<125μs/测量点)
·低固有噪声(-130dB)
·宽动态范围(>130dB)
·高频率分辨率(10μHz)
·校准时间短(<20s)
·有源彩色LCD(26cm) 技术指标
·Data only for 50Ω test sets.For 75Ω test sets and further details please refer to data sheet PD 757.1802.23.Unless otherwise stated,specifications apply to test ports PORT 1 and PORT2,a nominal source power of -10dBm at the test port and an IF bandwidth≤10kHz
·The arrow marks important data.
·Frequency range,measurement speed,dynamic range
·Frequency range
·Without External Measurements option
·ZVRL,ZVRE,ZVR
·with passive test set 50Ω or 75Ω|9kHz to 4Ghz
·with active test set 50Ω or 75Ω|300kHz to 4GHz
·ZVCE,ZVC
·with active test set 50Ω|20kHz to 8GHz
·With External Measurement option
·ZVRL,ZVRE,ZVR|10Hz to 4Ghz
·ZVCE,ZVC|20kHz to 8Ghz
·Relative frequency ·deviation|<2*10^-6+1*10^-6/a
·Resolution|10μHz
·Measurement speed(above 2Mhz)
·Number of points|1 to 2001(selectable)
·Measurement time per point|IF bandwidth(IFBW) 3kHz 10kHz 26kHz
with system errorcorrection <1.50μs <460μs <330μs
normalized <530μs <230μs <190μs
Fast Mode
with systemerror correction - - <240μs
normalized - - <125μs
·Dynamic range(without system error correction)
·ZVRL,ZVRE,ZVR
·(models ZVRL and ZVRE:at IF bandwidth 10Hz values are reduced by 5dB) IF bandwidth
With passive test set 50Ω 10Hz 3kHz 10kHz
20kHz to 20MHz >65dB,
typ.>110dB - -
200kHz to 20MHz >110dB >90dB >85dB
20MHz to 3Ghz >120dB >100dB >95dB
3Ghz to 4Ghz >110dB >90dB >85dB
With active test set 50Ω
300kHz to 1Mhz >107dB >87dB >82dB
1MHz to 20MHz >110dB >90dB >85dB
20MHz to 3Ghz >120dB >100dB >95dB
3Ghz to 4Ghz >110dB >90dB >85dB
With External Measurements option
50Hz to 200kHz >75dB - -
200kHzto 20MHz >110dB >95dB >90dB
20MHz to 1Ghz >130dB >110dB >105dB
1Ghz to 3Ghz >120dB >100dB >95dB
3Ghz to 4Ghz >110dB >95dB >90dB
·ZVCE,ZVC
·(mode ZVCE:at IF bandwidth 10Hz values are reduced by 5dB)
With active test set 50Ω
20kHz to 200kHz >60dB, - -
200kHzto 20MHz >100dB >80dB >75dB
20Mhz to 3Ghz >120dB >100dB >95dB
3Ghz to 4Ghz >110dB >90dB >85dB
4Ghz to 6Ghz >105dB >85dB >80dB
6Ghz to 8Ghz >100dB >80dB >75dB
With External/Measurements option
20kHz to 200kHz >75dB - -
200kHz to 20Mhz >110dB >95dB >90dB
20MHz to 1GHz >130dB >110dB >105dB
1Ghz to 3Ghz >120dB >100dB >95dB
3Ghz to 4Ghz >110dB >95dB >90dB
4GHz to 6GHz >105dB >90dB >85dB
6Ghz t o8GHz >100dB >85dB >80dB
Stability of measurement trace
per degree temperaturevariation
ZVRL,ZVRE,ZVR
<0.05dBor 0.4°
ZVCE,ZVC <0.1 dB or 1°
Measurement bandwidth
(IF bandwidth IFBW) 1Hz to 10kHz (half-decade steps)
and 26kHz(full)
·Measurement accuracy
·The following data are valid between 20℃ and 30℃ provided the instrument has reached thermal equilibrium (about 1 h after switch-on)and the tempera-ture has not varied by more than 1 degree after calibration.
·ZVRE and ZVR(bidirectional network analyzers)
·Accuracy of transmission measurements after full two-part system error cor-rection(TOSM)
·Specificaitons are based on a matched DUT and refer to a nominal source power of -10dBm at the test port.
·With test set 50Ω 300kHz to 4Ghz
at IF bandwidth 10Hz
·for+10dB to +3dB|<1dB or 6°
·for+3dB to -5dB|<0.2dB or 1°
·for -5dB to -60dB(passive|<0.05dB or 0.4°
·for-5dB to -60dB(active)|0.2dB or 1°
·for+3dB to -40dB|typ.<0.025dB
·for-60dB to -70dB|<0.2dB or 1°
·for-70dB to -80dB(ZVRE)|<1dB or 6°
·for-70dB to -85dB(ZVR)|<1dB or 6°
·Accuracy of reflection measurements
·after system error correction (TOSM or full one-port)
·Specificaitons are based on an isolationg DUT and refer to a nominal source power of - ·10dBm at the test port.
·With test set 50Ω
·It is assumed that the return loss of the match used for calibration is >46dB(effective system data:directivity Deff>46dB,test port match Seff>30dB).
·20kHz to 4Ghz(passive test set),
·300kHz to 4GHz(active test set)
·for+10dB to +3dB|<1dB or 6°
·for+3dB to -15dB|<0.4dB +0.04dB/Ghz,<3°+0.4°/Ghz
·for-15dB to -25dB|<1dB or 6°
·for-25dB to -35dB|<3dB or 20°
·ZVCE and ZVC
·Accuracy of transmission measurements
·after full two-part system error correction(TOSM)
·Specifications are based on a matched DUT and refer to a nominal source power of -20dBm at the test port.
·10MHz to 4Ghz
·at IF bandwidth 10Hz
·for +10dB to +3dB|<1dB or 6°
·for+3dB to -50dB|<0.2dB or 1°
·for+3dB to -40dB|typ.<0.025dB
·for-50dB to -60dB|<0.5dB or 4°
·for-60dB to -70dB(ZVCE)|<1dB or 6°
·for-60dB to -75dB(ZVC)|<1dB or 6°
4Ghz to 8Ghz
·at IF bandwidth 10Hz
·for+10dB to +3dB|<1dB or 6°
·for+3dB to -45dB|<0.2dB or 2°
·for+3dB to -40dB |typ.<0.025dB
·for-45dB to -55dB(ZVCE)|<1dB or 6°
·for-45dB to -60dB(ZVC)|<1dB or 6°
·Accuracy of reflection measurements
·after system error correction (TOSM or full one-port)
·Specifications are based on an isolaitng DUT and refer to a nominal source power of -20dBm at the test port.
·It is assumed that the return loss of the match used for calibration is >40dB(effective system data:directivity Deff>40dB,test port match Seff>30dB).
·20kHz to 8Ghz
·for+10dB to +3dB|<1dB or 6°
·for+3dB to - ·10dB|<0.4dB+0.04dB/GHz,<3°_0.4°/Ghz
·for=\-10dB to -20dB|<1dB or 6°
·for-20dB to -30dB|<3dB or 20°
·ZVRL(unidirectional network analyzer)
·Accuracy of transmission measurements
·after system error correction (one-path two-port)
·Specifications are based on a matched DUT and refer to a nominal source power of -10dBm at the test port.
·With test set 50Ω
·It is assumed that the return loss of the match used for calibration is >46dB(effective system data:directivity Deff>46dB,test port match Seff>30dB).
·20khz to 4Ghz
·for+10dB to +3dB|<1dB or 6°
·for+3dB to -15dB?|<0.4dB +0.04dB/Ghz,<3° +0.4°/Ghz
·for-15dB to -25dB|<2dB or 6°
·for-25dB to -35dB|<3dB or 20°
·Effective system characteristics(above 200kHz)
·These data are valid between 20℃ and 30℃ provided the instrument has reached thermal equilibrium(about 1h after swithc-on)and the temperature variations is not more than 1 degree after calibration.
ZVRE,ZVR,ZVCE,ZVC(bidirectional network analyzers)
·After full two-port system error correction(TOSM) ZVRE,ZVR ZVCE,ZVC
Direcivity >46dB^1) >40dB^2)
中赛仪器库存大量各种高频仪器现货特价出售中本公司长期现金回购各种高频仪器
选用二手测量仪器的优势是:
1、与新购仪器几个月的供货期相比,购买二手仪器的供货期要短的多。在 时间就是市场的今天,优势无疑是最为明显的。
2、二手仪器的价格便宜,基本为新购仪器价格的20%~50%。在电子技术迅 速发展的今天,仪器的更新也在加快,投资越少则风险越小。
3、为了让您放心地使用我们提供的二手仪器,我们销售的二手仪器可以做到:
1、保修半年至一年不等。
2、可以根据您的要求,将仪器送至国家级计量测试单位进行校准。
·高测量速度(<125μs/测量点)
·低固有噪声(-130dB)
·宽动态范围(>130dB)
·高频率分辨率(10μHz)
·校准时间短(<20s)
·有源彩色LCD(26cm) 技术指标
·Data only for 50Ω test sets.For 75Ω test sets and further details please refer to data sheet PD 757.1802.23.Unless otherwise stated,specifications apply to test ports PORT 1 and PORT2,a nominal source power of -10dBm at the test port and an IF bandwidth≤10kHz
·The arrow marks important data.
·Frequency range,measurement speed,dynamic range
·Frequency range
·Without External Measurements option
·ZVRL,ZVRE,ZVR
·with passive test set 50Ω or 75Ω|9kHz to 4Ghz
·with active test set 50Ω or 75Ω|300kHz to 4GHz
·ZVCE,ZVC
·with active test set 50Ω|20kHz to 8GHz
·With External Measurement option
·ZVRL,ZVRE,ZVR|10Hz to 4Ghz
·ZVCE,ZVC|20kHz to 8Ghz
·Relative frequency ·deviation|<2*10^-6+1*10^-6/a
·Resolution|10μHz
·Measurement speed(above 2Mhz)
·Number of points|1 to 2001(selectable)
·Measurement time per point|IF bandwidth(IFBW) 3kHz 10kHz 26kHz
with system errorcorrection <1.50μs <460μs <330μs
normalized <530μs <230μs <190μs
Fast Mode
with systemerror correction - - <240μs
normalized - - <125μs
·Dynamic range(without system error correction)
·ZVRL,ZVRE,ZVR
·(models ZVRL and ZVRE:at IF bandwidth 10Hz values are reduced by 5dB) IF bandwidth
With passive test set 50Ω 10Hz 3kHz 10kHz
20kHz to 20MHz >65dB,
typ.>110dB - -
200kHz to 20MHz >110dB >90dB >85dB
20MHz to 3Ghz >120dB >100dB >95dB
3Ghz to 4Ghz >110dB >90dB >85dB
With active test set 50Ω
300kHz to 1Mhz >107dB >87dB >82dB
1MHz to 20MHz >110dB >90dB >85dB
20MHz to 3Ghz >120dB >100dB >95dB
3Ghz to 4Ghz >110dB >90dB >85dB
With External Measurements option
50Hz to 200kHz >75dB - -
200kHzto 20MHz >110dB >95dB >90dB
20MHz to 1Ghz >130dB >110dB >105dB
1Ghz to 3Ghz >120dB >100dB >95dB
3Ghz to 4Ghz >110dB >95dB >90dB
·ZVCE,ZVC
·(mode ZVCE:at IF bandwidth 10Hz values are reduced by 5dB)
With active test set 50Ω
20kHz to 200kHz >60dB, - -
200kHzto 20MHz >100dB >80dB >75dB
20Mhz to 3Ghz >120dB >100dB >95dB
3Ghz to 4Ghz >110dB >90dB >85dB
4Ghz to 6Ghz >105dB >85dB >80dB
6Ghz to 8Ghz >100dB >80dB >75dB
With External/Measurements option
20kHz to 200kHz >75dB - -
200kHz to 20Mhz >110dB >95dB >90dB
20MHz to 1GHz >130dB >110dB >105dB
1Ghz to 3Ghz >120dB >100dB >95dB
3Ghz to 4Ghz >110dB >95dB >90dB
4GHz to 6GHz >105dB >90dB >85dB
6Ghz t o8GHz >100dB >85dB >80dB
Stability of measurement trace
per degree temperaturevariation
ZVRL,ZVRE,ZVR
<0.05dBor 0.4°
ZVCE,ZVC <0.1 dB or 1°
Measurement bandwidth
(IF bandwidth IFBW) 1Hz to 10kHz (half-decade steps)
and 26kHz(full)
·Measurement accuracy
·The following data are valid between 20℃ and 30℃ provided the instrument has reached thermal equilibrium (about 1 h after switch-on)and the tempera-ture has not varied by more than 1 degree after calibration.
·ZVRE and ZVR(bidirectional network analyzers)
·Accuracy of transmission measurements after full two-part system error cor-rection(TOSM)
·Specificaitons are based on a matched DUT and refer to a nominal source power of -10dBm at the test port.
·With test set 50Ω 300kHz to 4Ghz
at IF bandwidth 10Hz
·for+10dB to +3dB|<1dB or 6°
·for+3dB to -5dB|<0.2dB or 1°
·for -5dB to -60dB(passive|<0.05dB or 0.4°
·for-5dB to -60dB(active)|0.2dB or 1°
·for+3dB to -40dB|typ.<0.025dB
·for-60dB to -70dB|<0.2dB or 1°
·for-70dB to -80dB(ZVRE)|<1dB or 6°
·for-70dB to -85dB(ZVR)|<1dB or 6°
·Accuracy of reflection measurements
·after system error correction (TOSM or full one-port)
·Specificaitons are based on an isolationg DUT and refer to a nominal source power of - ·10dBm at the test port.
·With test set 50Ω
·It is assumed that the return loss of the match used for calibration is >46dB(effective system data:directivity Deff>46dB,test port match Seff>30dB).
·20kHz to 4Ghz(passive test set),
·300kHz to 4GHz(active test set)
·for+10dB to +3dB|<1dB or 6°
·for+3dB to -15dB|<0.4dB +0.04dB/Ghz,<3°+0.4°/Ghz
·for-15dB to -25dB|<1dB or 6°
·for-25dB to -35dB|<3dB or 20°
·ZVCE and ZVC
·Accuracy of transmission measurements
·after full two-part system error correction(TOSM)
·Specifications are based on a matched DUT and refer to a nominal source power of -20dBm at the test port.
·10MHz to 4Ghz
·at IF bandwidth 10Hz
·for +10dB to +3dB|<1dB or 6°
·for+3dB to -50dB|<0.2dB or 1°
·for+3dB to -40dB|typ.<0.025dB
·for-50dB to -60dB|<0.5dB or 4°
·for-60dB to -70dB(ZVCE)|<1dB or 6°
·for-60dB to -75dB(ZVC)|<1dB or 6°
4Ghz to 8Ghz
·at IF bandwidth 10Hz
·for+10dB to +3dB|<1dB or 6°
·for+3dB to -45dB|<0.2dB or 2°
·for+3dB to -40dB |typ.<0.025dB
·for-45dB to -55dB(ZVCE)|<1dB or 6°
·for-45dB to -60dB(ZVC)|<1dB or 6°
·Accuracy of reflection measurements
·after system error correction (TOSM or full one-port)
·Specifications are based on an isolaitng DUT and refer to a nominal source power of -20dBm at the test port.
·It is assumed that the return loss of the match used for calibration is >40dB(effective system data:directivity Deff>40dB,test port match Seff>30dB).
·20kHz to 8Ghz
·for+10dB to +3dB|<1dB or 6°
·for+3dB to - ·10dB|<0.4dB+0.04dB/GHz,<3°_0.4°/Ghz
·for=\-10dB to -20dB|<1dB or 6°
·for-20dB to -30dB|<3dB or 20°
·ZVRL(unidirectional network analyzer)
·Accuracy of transmission measurements
·after system error correction (one-path two-port)
·Specifications are based on a matched DUT and refer to a nominal source power of -10dBm at the test port.
·With test set 50Ω
·It is assumed that the return loss of the match used for calibration is >46dB(effective system data:directivity Deff>46dB,test port match Seff>30dB).
·20khz to 4Ghz
·for+10dB to +3dB|<1dB or 6°
·for+3dB to -15dB?|<0.4dB +0.04dB/Ghz,<3° +0.4°/Ghz
·for-15dB to -25dB|<2dB or 6°
·for-25dB to -35dB|<3dB or 20°
·Effective system characteristics(above 200kHz)
·These data are valid between 20℃ and 30℃ provided the instrument has reached thermal equilibrium(about 1h after swithc-on)and the temperature variations is not more than 1 degree after calibration.
ZVRE,ZVR,ZVCE,ZVC(bidirectional network analyzers)
·After full two-port system error correction(TOSM) ZVRE,ZVR ZVCE,ZVC
Direcivity >46dB^1) >40dB^2)
中赛仪器库存大量各种高频仪器现货特价出售中本公司长期现金回购各种高频仪器
选用二手测量仪器的优势是:
1、与新购仪器几个月的供货期相比,购买二手仪器的供货期要短的多。在 时间就是市场的今天,优势无疑是最为明显的。
2、二手仪器的价格便宜,基本为新购仪器价格的20%~50%。在电子技术迅 速发展的今天,仪器的更新也在加快,投资越少则风险越小。
3、为了让您放心地使用我们提供的二手仪器,我们销售的二手仪器可以做到:
1、保修半年至一年不等。
2、可以根据您的要求,将仪器送至国家级计量测试单位进行校准。
相关产品推荐